RV 150.1 | RV 150.H | RV 250.1 | RV 360.1 | ||
Geometric volume | cm³/Rev. | 97,7 | 97,7 | 167 | 242 |
Geometric capacity at n = 1500 min-1 | l/min | 146 | 146 | 250 | 363 |
Continuous Pressure according to DIN 24312 | bar | 350 | 420 | 350 | 315 |
Maximum Pressure according toDIN 24312 | bar | 450 | 450 | 450 | 400 |
Required oil flow for casing flushing | l/min | 8 | 8 | 10 | 14 |
Minimum control time from 0-100% stroke | ms | 45 | 45 | 52 | 55 |
External leakage at pa = 315 bar and 35 cSt | l/min | 8,5 | 8,5 | 13 | 18 |
Speed range for self priming operation (0,9 bar absolute) | 1/min | 500-1500 | 500-1500 | 500-1500 | 500-1000 |
for pre-filling pe = 2 bar | 1/min | 200-1500 | 200-1500 | 200-1500 | 200-1500 |
Maximum allowable radial load at shaft end (flexible coupling required) | N | 500 | 500 | 750 | 1000 |
Moment of inertia | kgm² | 0,0676 | 0,0676 | 0,164 | 0,258 |
Weight | kg | 150 | 150 | 207 | 300 |
Method of fastening | Foot / Flange | Foot / Flange | Flange | Foot / Flange |
All RV-types | |||||
---|---|---|---|---|---|
Inlet pressure | up to continuous pressure | ||||
Pressure liquid | Hydraulic oil HLP according to DIN 51524-2 | ||||
Pressure liquid viscosity | 20-75 cSt | ||||
Allowable start viscosity | |||||
at pe = 1 bar absolute | 150 cSt | ||||
at pe = 2 bar absolute | 400 cSt | ||||
Pressure liquid temperature | 10-65°C | ||||
Purity class according to ISO 4406 | 19/16/13 | ||||
Leakage flow pressure (casing pressure) | max. 2 bar absolute |